RECALL DATALOGGER: How to recall all measurements stored in a tool LOGGER

IMPORTANT:

1) This STANDARD PROCEDURE is valid for all ROVER and PRIME DIGITAL models with SINGLE DISPLAY TFT color, writing and graphics can vary from model to model;
2) For TOUCH-SCREEN models, you can select functions directly without rotating the ENCODER.

For the HD TAB 4, TAB 7, TAB 700, TAB 9, TAB 900 and PROTAB Series
For the EASY METER of PRIME DIGITAL Series
For the HD LIGHT, COMPACT, FLASH, TOUCH and PRO
For the ATOM LIGHT Series
ATOM POWER, DIGICUBE and TOUCHMETER

The "REQUIRED DATALOGGER" function allows you to recall all measures (LOGGER) previously stored in the instrument.

NOTE: Before creating a LOGGER, click here and consult the following "FAQ": "SAVE DATALOGGER: How to automatically record and record all the measurements of various TV and CATV channels already pre-tuned to an AUTOMATIC or MANUAL memory plan and save them to the DATA LOGGER".

Measurements (LOGGER) can also be displayed or printed through the "ROVER-S.M.A.R.T. interface PC program".
Please note that the interface S.M.A.R.T. program supports Windows operating systems only and cannot supports MAC operating systems.

  • Click here if you want to download the "ROVER S.M.A.R.T. interface program user guide" in pdf format.

STANDARD PROCEDURE:

1) Turn on the instrument,

2) Make sure you have selected your language,

3) Rotate the encoder and select the "MEMORY" icon (see figure 1),

ROVER_HD_Series_MEMORY
Figure 1: HOME MENU, MEMORY icon selection

4) Press the encoder to confirm,

5) Rotate the encoder and select "RECALL DATALOGGER" (see Figure 2),

ROVER_HD_Series_MEMORY_MENU_RECALL_DATALOGGER 
Figure 2: Select "RECALL DATALOGGER"

6) Press the encoder to confirm,

7) Rotate the encoder and select the "Data File" entry (see Figure 3),

8) Press the encoder to confirm,

9) Rotate the encoder and select "LOG" (LOGGER) where the measurements have been saved, for example "LOG. 1" (see figure 3),

  • NOTE: Available loggers are 99. The logger is the root directory where you can save all the measurements later: "POINT 1", "POINT 2", "POINT 3", and so on;
  • The main folder eg. "LOG 1", "LOG 2", "LOG 3" etc. identifies the house, building or staircase inside a condominium (eg Scale A, B, C, etc.), while "POINT 1", "POINT 2", "POINT 3" etc. represent the single TV socket inside the apartment.
 ROVER_HD_Series_RECALL_DATALOGGER_LOG_1
 Figure 3: Selecting the LOG number to call, for example "LOG. 1"

10) Press the encoder to confirm,

11) Rotate the encoder and select the item "Point:" (see figure 4),

  • NOTE: Point is the same as the number where the measurements were previously saved, eg "POINT 1" (see figure 4),

12) Rotates the encoder and selects the "POINT" to be called, for example "POINT 1" (see figure 4),

ROVER_HD_Series_RECALL_DATALOGGER_POINT_1 
Figure 4: Selecting POINT number to call, for example "POINT 1"

13) Press the encoder to confirm,

14) Rotate the encoder and select "RECALL?" (See Figure 5),

 ROVER_HD_Series_RECALL_DATALOGGER_RECAL
 Figure 5: Select "RECALL?"

15) Press the encoder to confirm,

16) Rotate the encoder to navigate the measurements (see figure 6),

 ROVER_HD_Series_RECALL_DATALOGGER
Figure 6: Example of DATALOGGER, channels / measurements.

17) Press the encoder to select "EXIT" and press it again to exit the screen (see figure 7) and return to the "LOG" and "POINT" selection screen (see figure 5).

ROVER_HD_Series_RECALL_DATALOGGER_EXIT 
Figure 7: "EXIT" selection

NOTE: The MENU (written and graphic) of the figures shown in the following "F.A.Q." may vary from model to model or depending on SW upgrade.